Drybench Bioreactor.
Scale-up calculator: constant P/V, tip speed or kLa
Agitation at a larger scale by three rules side by side: constant power per volume, constant tip speed and constant kLa, with their assumptions stated.
Agitation at a larger, geometrically similar vessel by three rules side by side, at the same gas flow per volume: constant ungassed power per volume, constant impeller tip speed and constant kLa by Van 't Riet's correlation. They disagree because a larger vessel at the same vvm has a higher superficial gas velocity.
Large vessel: diameter 1.02 m, impeller 0.408 m, 700 L.
| Rule | Agitation (rpm) | Tip speed (m/s) | kLa (per hour) | Pg/V (W/m³) |
|---|---|---|---|---|
| The small vessel | 600 | 2.76 | 106 | 1,890 |
| Constant P/V | 216 | 4.61 | 215 | 1,620 |
| Constant tip speed | 129 | 2.76 | 120 extrapolated | 376 |
| Constant kLa | 116 | 2.48 | 106 extrapolated | 277 |
The small vessel
- Agitation (rpm)
- 600
- Tip speed (m/s)
- 2.76
- kLa (per hour)
- 106
- Pg/V (W/m³)
- 1,890
Constant P/V
- Agitation (rpm)
- 216
- Tip speed (m/s)
- 4.61
- kLa (per hour)
- 215
- Pg/V (W/m³)
- 1,620
Constant tip speed
- Agitation (rpm)
- 129
- Tip speed (m/s)
- 2.76
- kLa (per hour)
- 120 extrapolated
- Pg/V (W/m³)
- 376
Constant kLa
- Agitation (rpm)
- 116
- Tip speed (m/s)
- 2.48
- kLa (per hour)
- 106 extrapolated
- Pg/V (W/m³)
- 277
Unverified: Van 't Riet's range not yet checked against Van 't Riet 1979.
Ignores cooling, mixing time and shear. Every kLa is the correlation's, flagged outside its fitted range, with no prediction interval.
Agitation in the large vessel, by each rule:
Constant P/V 216 rpm
Constant tip speed 129 rpm; kLa extrapolated
Constant kLa 116 rpm; kLa extrapolated
Tank and impeller diameters and the ungassed liquid height are drawn to one scale; the headspace and the impeller's position are not to scale. Each rule gives its own agitation; the numbers are in the table, and none of the three is recommended here.
Each rule's agitation and tip speed from its scaling rule, and kLa and Pg/V from the correlations, at the small and the large vessel; nothing here is measured.
Unverified: Van 't Riet's range not yet checked against Van 't Riet 1979.
Limits
- Teaching and estimation model, not a validated process model.
- The rescue cascade stays within the agitation, gas-flow and oxygen-enrichment limits you enter, and ignores cooling capacity, vessel pressure and gas-safety limits. Oxygen enrichment near flammable solvents or vapours is a fire and explosion hazard. Do not run a vessel from these outputs without your own engineering review.
A simulation, not a forecast. Every output follows from the model equations and the parameters you entered. It is a teaching and estimation model, not a validated process model, and not a prediction for any real strain, vessel or process.